Uneven bed looseness between the left and right sides of a jig: first check the level of the screen plates, as well as the distribution of make-up water and feed material.

One of the most troublesome scenarios for operators of a jig is when the bed on the left side becomes overly loose and fluid, while the bed on the right side appears compacted. Simply increasing the pulsation frequency in such cases often exacerbates the instability on the left without resolving the compaction on the right. This is because the root cause may not lie with the pulsation source itself, but rather with fundamental imbalances between the two sides-such as differences in actual water flow, bed thickness, or feed load.
Begin by verifying the mechanical alignment while the machine is shut down.
The screen plate must be perfectly level, and the screen apertures and hold-down bars must be uniform-ensuring they are not blocked on one side while remaining clear on the other. Furthermore, the thickness, particle size distribution, and density of the bed media (ragging) must be consistent across both sides. If the equipment foundation has settled or the screen plate has become deformed, the flow resistance will inevitably differ between the two sides, regardless of how well the operating parameters are adjusted. It is inadvisable to rely on valve adjustments as a long-term fix before the mechanical alignment has been properly corrected.
Flow distribution is more critical than total flow rate.
The main water meter only indicates the total volume of water entering the equipment; it does not guarantee that the flow passing through the bed is equal on both sides. Factors such as the water distribution tank level, the configuration of branch pipe elbows, valve settings, or blockages beneath the screen can all lead to uneven flow (mal-distribution). During commissioning, you can briefly collect the discharge from each side separately or observe the degree of bed expansion to verify whether there is any imbalance in the water flow.
Uneven loading causes one side to become increasingly compacted.
If the feed chute fails to distribute material evenly, coarse particles and heavy minerals may concentrate on one side. This causes the bed to thicken locally, requiring more energy to maintain a loose, fluidized state. Conversely, the side with a lighter load may appear highly active, but this can inadvertently cause fine, heavy minerals to be carried over into the tailings. To address this, adjust the feed drop point and the distribution plate to ensure that the load per unit width is balanced across both sides.
Before adjusting the pulsation, ensure that the operating conditions on both sides are aligned. Once the mechanical components, water supply system, and ore feed have been calibrated, proceed to adjust the frequency, stroke, and discharge. Modify only one primary variable at a time, and observe whether the bed's lifting, suction, and settling phases occur synchronously. If a significant phase difference persists between the two sides, inspect the drive mechanism and the diaphragm system-do not simply continue increasing the water flow or the frequency.